Line 5: | Line 5: | ||
[[: | [[: | ||
- | The latest software for the operator panel (PLC) is denoted **1.15**. The latest firmware is denoted **15.40**. | + | The latest software for the operator panel (PLC) is denoted **1.18**. The latest firmware is denoted **15.52**. |
- | The latest software for the control electronics (PCB) is denoted **1.20** (denoted 1.19 for older electronics revisions). | + | The latest software for the control electronics (PCB) is denoted **1.24** (denoted 1.23 for older electronics revisions). |
---- | ---- | ||
===== PLC software change log ===== | ===== PLC software change log ===== | ||
+ | |||
+ | ==== 1.18 (2022-06-08) ==== | ||
+ | |||
+ | **Fixed issues ** \\ | ||
+ | Updated default communication server settings | ||
+ | |||
+ | ==== 1.17 (2021-09-22) ==== | ||
+ | |||
+ | **New features** \\ | ||
+ | Delayed start of first recipe, set in hours\\ | ||
+ | Robot tries to untangle stuck hose reel between recipes by moving forward 1000 pulses\\ | ||
+ | Power to telescope automatically increased beyond position 375 if stuck | ||
+ | |||
+ | **Improvements ** \\ | ||
+ | Feedback on notification feature termination\\ | ||
+ | Soft alarms are no longer flashed during automatic washing, but still found in alarm list\\ | ||
+ | Time limit for low water pressure alarm is increased to 120 s (from 30) | ||
+ | |||
+ | **Fixed issues ** \\ | ||
+ | Removed possibility to set 0 as last marker number | ||
==== 1.15 (2020-06-11) ==== | ==== 1.15 (2020-06-11) ==== | ||
Line 67: | Line 87: | ||
===== PCB software change log ===== | ===== PCB software change log ===== | ||
- | ==== 1.20 (2019-05-02) ==== | + | ==== 1.24 (2021-11-10) ==== |
- | Softer ramping | + | Minor correction |
- | Delay PLC power on | + | ==== 1.22 (2021-03-19) ==== |
+ | Faster start of hose reel motor | ||
+ | |||
+ | ==== 1.20 (2019-05-02) ==== | ||
+ | |||
+ | Softer ramping of power to the hose reel motor\\ | ||
+ | Delay PLC power on\\ | ||
Updated current measurement algorithm | Updated current measurement algorithm | ||
Line 81: | Line 107: | ||
---- | ---- | ||
- | ===== PLC firmware change log ===== | + | ===== PLC firmware change log ===== |
+ | |||
+ | ==== 15.52 ==== | ||
- | ==== 15.40 ==== | + | Manufacturer fixed issue where it was possible for the unit to get stuck while booting which could result in complete backup battery drain if left unresolved\\ |
+ | Manufacturer fixed issue where units were not shutting down properly when backup battery voltage was below 2.0 V | ||
- | Manufacturer fixed issue with backup battery possibly being drained after quick power toggles | + | ==== 15.40 ==== |
+ | Manufacturer fixed issue with backup battery possibly being drained after quick power toggles\\ | ||
Manufacturer fixed issue with false failing selftests due to backup batteryand loss of data | Manufacturer fixed issue with false failing selftests due to backup batteryand loss of data | ||