Next revisionBoth sides next revision
service:software [2021/05/17 01:34] userservice:software [2022/06/08 07:14] user
Line 5: Line 5:
 [[:service:plc_sw_revision|See what version your robot runs on]] [[:service:plc_sw_revision|See what version your robot runs on]]
  
-The latest software for the operator panel (PLC) is denoted **1.16**. The latest firmware is denoted **15.50**.+The latest software for the operator panel (PLC) is denoted **1.18**. The latest firmware is denoted **15.52**.
  
-The latest software for the control electronics (PCB) is denoted **1.22** (denoted 1.21 for older electronics revisions).+The latest software for the control electronics (PCB) is denoted **1.24** (denoted 1.23 for older electronics revisions).
  
 ---- ----
Line 13: Line 13:
 ===== PLC software change log ===== ===== PLC software change log =====
  
-==== 1.16 (2021-05-17) ====+==== 1.18 (2022-06-08) ==== 
 + 
 +**Fixed issues ** \\ 
 +Updated default communication server settings 
 + 
 +==== 1.17 (2021-09-22) ====
  
 **New features** \\ **New features** \\
Line 23: Line 28:
 Feedback on notification feature termination\\ Feedback on notification feature termination\\
 Soft alarms are no longer flashed during automatic washing, but still found in alarm list\\ Soft alarms are no longer flashed during automatic washing, but still found in alarm list\\
-Hose spreader stops moving if hose reel has not moved for 5 s\\ 
 Time limit for low water pressure alarm is increased to 120 s (from 30) Time limit for low water pressure alarm is increased to 120 s (from 30)
  
Line 83: Line 87:
 ===== PCB software change log ===== ===== PCB software change log =====
  
-==== 1.22 (2021-03-19)  ====+==== 1.24 (2021-11-10) ==== 
 + 
 +Minor correction of hose reel standby control 
 + 
 +==== 1.22 (2021-03-19) ====
  
 Faster start of hose reel motor Faster start of hose reel motor
Line 101: Line 109:
 ===== PLC firmware change log ===== ===== PLC firmware change log =====
  
-==== 15.50 ====+==== 15.52 ====
  
-Manufacturer fixed issue where it was possible for the unit to get stuck while booting which could result in complete backup battery drain if left unresolved \\+Manufacturer fixed issue where it was possible for the unit to get stuck while booting which could result in complete backup battery drain if left unresolved\\
 Manufacturer fixed issue where units were not shutting down properly when backup battery voltage was below 2.0 V Manufacturer fixed issue where units were not shutting down properly when backup battery voltage was below 2.0 V