 ===== First marker not found within 500 pulses ===== ===== First marker not found within 500 pulses =====
  
-This is a [[:troubleshooting_alarm_hard_alarms|hard]] alarm.+This is a [[troubleshooting:hard_alarms|hard]] alarm.
  
 ==== Description ==== ==== Description ====
Line 9: Line 9:
 ==== Troubleshooting ==== ==== Troubleshooting ====
  
-  * Check that the magnetic switch arm is in the correct position (both height and length)+  * Check that the [[parts:comp_marker_switch|magnetic switch]] arm is in the correct position (both height and length)
   * Check that the marker is mounted properly   * Check that the marker is mounted properly
-  * Check that the magnetic switch is working +  * Check that the [[parts:comp_marker_switch|magnetic switch]] is working 
-  * Check that the robot was placed within 1 m of the first marker +  * Check that the robot was placed within 1 m from the first marker 
-  * Check that the distance from the magnetic switch to the marker is less than 10 cm+  * Check that the distance from the [[parts:comp_marker_switch|magnetic switch]] to the marker is less than 10 cm