troubleshooting:no_alarm:lost_memory [2020/09/14 00:10] – [Lost position] joachimtroubleshooting:no_alarm:lost_memory [2020/09/25 01:25] (current) – [Lost clock] joachim
Line 13: Line 13:
 Lost positions will show when robot parks incorrectly between washing programs or when it does not wash where it should. [[:troubleshooting:no_alarm:robot_positions_incorrect|Read more about possible explanations for incorrect positioning here]]. Lost positions will show when robot parks incorrectly between washing programs or when it does not wash where it should. [[:troubleshooting:no_alarm:robot_positions_incorrect|Read more about possible explanations for incorrect positioning here]].
  
 +==== Lost homing ====
  
-==== Lost homing  ====+If the homing is lost the robot will show an alarm ([[:troubleshooting:alarm:homing_needed|]]) when trying to start an automatic wash. It will also show as red circles on the detailed manual screen. If your EVO Cleaner needs a new homing, see [[:service:service_instructions:homing_instruction|this Homing instruction.]]
  
-If the homing is lost the robot will show an alarm when trying to start an automatic wash. It will also show as red circles on the detailed manual screen.+Lost homing can also mean lost parking positions, which will show when robot parks incorrectly between washing programs.
  
-==== Lost clock  ====+==== Lost clock ==== 
 + 
 +The clock is seen in the top right corner on the start screen. Date is seen on the [[:user_manuals:screens#settings_screen|Settings screen]]. A lost clock sets the date and time to 1996-01-01 00:00.
  
-The clock is seen in the top right corner on the [[:user_manuals:screens#start_screen|Start screen]]. Date is seen on the [[:user_manuals:screens#settings_screen|Settings screen]]. A lost clock sets the date and time to 1996-01-01 00:00. 
  
 ===== Troubleshooting ===== ===== Troubleshooting =====
  
-  * Redo the initialization+  * Redo the [[:service:service_instructions:homing_instruction|initialization]]
   * Check that battery connectors are firmly attached, ie. no loose contact, and that the cables are not damaged. A panel that is restarted very frequently can loose positions.   * Check that battery connectors are firmly attached, ie. no loose contact, and that the cables are not damaged. A panel that is restarted very frequently can loose positions.
   * Check for damaged panel, especially for holes in the overlay and cracks in the housing. Water ingress can lead to lost data.   * Check for damaged panel, especially for holes in the overlay and cracks in the housing. Water ingress can lead to lost data.