| The batteries must be recharged in a well-ventilated area free of flammable materials. | The batteries must be recharged in a well-ventilated area free of flammable materials. | ||
| - | Keep the batteries' | + | Keep the battery |
| ---- | ---- | ||
| - | ===== Standard type ===== | + | ===== Type ===== |
| - | The batteries included with the robot are 2 standard | + | The batteries included with the robot are two 12 V AGM type lead acid batteries with 100 Ah capacity (part no 909244). If replaced, it's important that the batteries have the correct size and weight. Are the batteries |
| - | Weight: | + | Weight: |
| - | Length: | + | Length: |
| - | Width: | + | Width: |
| - | Height: | + | Height: |
| + | |||
| + | It's recommended to replace both batteries at once as imbalance can shorten lifespan. It's recommended to use batteries suitable for deep-cycling. | ||
| Link: **[[: | Link: **[[: | ||
| - | |||
| - | ---- | ||
| - | |||
| - | ===== AGM type ===== | ||
| - | |||
| - | Optionally the robot can be equipped with AGM type batteries (part no, 909244). Compared with the standard type batteries th run time increases significantly with the AGM batteries. In addition to that, AGM batteries are more durable and have a longer life span compared to the standard batteries. | ||
| ---- | ---- | ||
| Line 39: | Line 35: | ||
| 1. When charging the batteries, the robot must be switched off. The batteries cannot be charged when the robot is on. | 1. When charging the batteries, the robot must be switched off. The batteries cannot be charged when the robot is on. | ||
| - | < | ||
| 2. The charger must be connected to the robot first. | 2. The charger must be connected to the robot first. | ||
| - | < | ||
| 3. Then connect to the wall outlet. | 3. Then connect to the wall outlet. | ||
| - | < | ||
| 4. When the charger is connected to the wall outlet only the orange status light should be turned on. See the charger manual for details. | 4. When the charger is connected to the wall outlet only the orange status light should be turned on. See the charger manual for details. | ||
| Line 53: | Line 46: | ||
| If the robot has warned for low battery, charge it for at least the same amount of time that it has previously been washing before using it again. | If the robot has warned for low battery, charge it for at least the same amount of time that it has previously been washing before using it again. | ||
| + | Store the robot in a heated room while charging as cold temperature can decrease battery life span. | ||