Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
troubleshooting:alarm:water_pressure_too_low [2023/05/08 06:46] – [Description] joachim | troubleshooting:alarm:water_pressure_too_low [2024/08/21 11:08] (current) – user | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Water pressure too low ====== | ====== Water pressure too low ====== | ||
- | This is a [[troubleshooting: | + | This is a [[:troubleshooting: |
===== Description ===== | ===== Description ===== | ||
Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes. | Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes. | ||
- | |||
===== Troubleshooting ===== | ===== Troubleshooting ===== | ||
* Check the water hose for damages/ | * Check the water hose for damages/ | ||
- | * Check on the right side of hose reel if lock ring has jumped off | + | * Check on the right side of hose reel if lock ring is positioned correctly |
* Check swivel and hose that goes to the magnetic valve for damages/ | * Check swivel and hose that goes to the magnetic valve for damages/ | ||
* Check that the pressure washer delivers water with sufficient pressure | * Check that the pressure washer delivers water with sufficient pressure | ||
+ | * Check that the flow is sufficient to the pressure washer and that there is no too much water directed elsewhere in the facilities | ||
+ | * Make sure the pressure washer is in good condition. Pressure washers needs service too. | ||
+ | * Check that the strainer at the end of the long hose is clean from debris | ||