Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| troubleshooting:alarm:water_pressure_too_low [2023/05/08 06:46] – [Description] joachim | troubleshooting:alarm:water_pressure_too_low [2024/08/21 11:08] (current) – user | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Water pressure too low ====== | ====== Water pressure too low ====== | ||
| - | This is a [[troubleshooting: | + | This is a [[:troubleshooting: |
| ===== Description ===== | ===== Description ===== | ||
| Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes. | Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes. | ||
| - | |||
| ===== Troubleshooting ===== | ===== Troubleshooting ===== | ||
| * Check the water hose for damages/ | * Check the water hose for damages/ | ||
| - | * Check on the right side of hose reel if lock ring has jumped off | + | * Check on the right side of hose reel if lock ring is positioned correctly |
| * Check swivel and hose that goes to the magnetic valve for damages/ | * Check swivel and hose that goes to the magnetic valve for damages/ | ||
| * Check that the pressure washer delivers water with sufficient pressure | * Check that the pressure washer delivers water with sufficient pressure | ||
| + | * Check that the flow is sufficient to the pressure washer and that there is no too much water directed elsewhere in the facilities | ||
| + | * Make sure the pressure washer is in good condition. Pressure washers needs service too. | ||
| + | * Check that the strainer at the end of the long hose is clean from debris | ||