 ====== Water pressure too low ====== ====== Water pressure too low ======
  
-This is a [[troubleshooting:hard_alarms|hard]] alarm.+This is a [[:troubleshooting:hard_alarms|hard]] alarm.
  
 ===== Description ===== ===== Description =====
  
 Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes. Low water pressure was detected. The water pressure was below about 50 bar for more than 2 minutes.
- 
  
 ===== Troubleshooting ===== ===== Troubleshooting =====
  
   * Check the water hose for damages/leakage   * Check the water hose for damages/leakage
-  * Check on the right side of hose reel if lock ring has jumped off+  * Check on the right side of hose reel if lock ring is positioned correctly
   * Check swivel and hose that goes to the magnetic valve for damages/leakage (right hose reel side has to be taken off)   * Check swivel and hose that goes to the magnetic valve for damages/leakage (right hose reel side has to be taken off)
   * Check that the pressure washer delivers water with sufficient pressure   * Check that the pressure washer delivers water with sufficient pressure
-  * Make sure the pressure washer is in good condition. Pressure washers needs service too.+      * Check that the flow is sufficient to the pressure washer and that there is no too much water directed elsewhere in the facilities 
 +      * Make sure the pressure washer is in good condition. Pressure washers needs service too. 
 +  * Check that the strainer at the end of the long hose is clean from debris